Model : BSC-IIB2-1100; BSC-IIB2-1400; BSC-IIB2-1500; BSC-IIB2-1800

Airflow System : 100% air exhaust
Max Opening Height : 400 mm
Downflow Velocity : 0.35m/s±0.025m/s
Inflow Velocity : 0.52m/s±0.025m/s
B2 biosafety cabinets with advanced ergonomic design that excels in user comfort and functionality
You can later choose whether you want a quote, or if you place a firm order.

Product Description

The biohazard safety cabinet class ii is biological safety isolation equipment used in biological safety laboratories or other laboratories, It can prevent harmful or unknown biological particulate aerosol from escaping during operation, it’s suitable for experiments with radioactive nuclides and volatile chemicals.

BSC Class II Type B2 Specifications:

Model BSC-IIB2-1100 BSC-IIB2-1400 BSC-IIB2-1500 BSC-IIB2-1800
External Size (WxDxH)(mm) 1050×780×2180 1400×780×2180 1500×780×2180 1800×780×2180
Internal Size (WxDxH)(mm) 950×626×600 1300×626×600 1400×626×600 1700×626×600
Tested Opening Safety height 200mm (8”)
Max.Opening 400mm
Work Surface Height 800mm
Control System Display LCD touch screen
Alarm Abnormal airflow velocity, ULPA filter failure, UV lamp failure, Front window at unsafe height
Airflow System Airflow Mode 100% air exhaust
Downflow Velocity 0.35m/s±0.025m/s
Inflow Velocity 0.52m/s±0.025m/s
Inflow Air Volume 355m³/h (209CFM) 486m³/h (286CFM) 524m³/h (309CFM) 636m³/h (375CFM)
Downflow Air Volume 718m³/h (423CFM) 983m³/h (579CFM) 1058m³/h (623CFM) 1285m³/h (757CFM)
Exhaust Air Volume 1073m³/h (632CFM) 1469m³/h (865CFM) 1582m³/h (932CFM) 1921m³/h (1131CFM)
Air filtration System ULPA Filter 2pcs ULPA filter, ≥99.9995% efficiency at 0.1~0.3 μm, filter life indicator
Cleanliness Grade Class 100 (ISO14644.1 Class 5)
Cabinet Construction Main Body Electro-galvanized steel with antimicrobial Powder Coating
Work Surface 304 stainless steel
Front Window Motorized, Two-layer laminated toughened glass ≥ 5mm. Anti UV.
Electrical System UV Lamp 20Wx1 30Wx1 30Wx1 40Wx1
Emission of 253.7 nanometers for most efficient decontamination,UV life indicator, UV timer.
LED Lamp 16Wx2 20Wx2 20Wx2 20Wx2
Max.Consumption 1550W (Not include socket loading power consumption)
Power Supply AC220V±10%, 50/60Hz; 110V±10%, 60Hz
Illumination ≥1000Lux
Sound Emission ≤65dB(A) ≤67dB(A)
Vibration of Work Surface ≤5μm
Standard Accessory 1. Base Stand;

2. Air Velocity Sensor;

3. ULPA FIlter;

4. LCD Touch Screen;

5. LED Lamp×2;

6. UV Lamp×1;

7. Waterprof Socket×2;

8. Motorized Front Window;

9. Footmaster Caster;

10. Foot Switch;

11. Electric Air Valve Control;

12. Exhaust Blower;

13. 6m Exhaust Duct (Φ300mm);

14. RS485 interface

Optional Accessory 1. LED Lights With Adjustable Brightness

2. Gas Tap;

3. Water Tap;

4. IV Bar With Hooks;

5. Manual Adjustable Base Stand;

6. Arm rest

Net Weight (kg) 289.5 323 350 430
Gross Weight (kg) 346 404 435 550
Shipping Size (WxDxH)(mm) Main Unit 1150x1080x1710 1550x1120x1710 1650x1120x1710 1950x1120x1710
Exhaust Blower 730x660x500 700x700x500 700x700x500 700x700x500
Shipping Volume (m³) 2.6 3.3 3.5 4

Protection: Operator, Samples and the environment.

Airflow System: 100% air exhaust

Work area: Negative pressure

Biosafety Cabinet Class II Features:

  1. Standard with Air velocity sensor. Real-time monitoring and display Air velocity.
  2. Standard with Foot switch. Controls the front window to up and down.
  3. Standard with Electric Air valve control. It can be controlled through the LCD touch screen.
  4. Standard with RS485 interface.
  5. Depth of the cabinet is reduce to 780mm. Better access to the door of laboratory room.
  6. Unibody design for front panel. Better sealing and safer than the splice style front panel.
  7. Base stand with foot support for operator comfortable operation.
  8. Optional LED lamp with adjustable brightness.
  9. Safety login system: three-level authority, control,function setting, parameter setting and hierarchical menu entry can be performed. 

     

 

Safety Performance:

  1. UV sterilization function and timing function can be set by appointment.
  2. Automatic air speed adjustable.
  3. With memory function in case of power-failure.
  4. Audio and visual alarm (Abnormal airflow velocity, filter failure, UV lamp failure, Front window at unsafe height).
  5. Interlock function: UV lamp and front window; UV lamp and blower, LED lamp; Blower and front window.
<< return to products

Aviklab | Laboratory Equipment & Build

With over 15 years of experience in building labs, multitudinous supply of lab equipment and after sales services, We are ready to provide Consultation services , sales of equipment , maintenance , repair and calibration services

AVIK Laboratory Resources (M) Sdn. Bhd.
B03-1, 1st Floor, Block B,
Garden City Business Center,
Jalan Dagang Besar,
68000 Ampang,
Selangor

Telephone  +60163841559

Copyright © 2024 Aviklab Sdn Bhd